Diatest Split-ball probes are flexible and universal bore gauges for indicating internal measurements The modular design with extensive accessories enables gauging of most common bores. This allows a use for serial and individual control as well as preferentially in the plant directly at the production machine. Range of application: Standard probes, hard chrome plated: Ø 0.47 – 41.1mm Standard probes, carbide inserted:Ø 1.5 – 41.1 mm Standard probes, ceramic inserted: Ø 3.7 – 41.1 mm Blind bore probes, hard chrome plated: Ø 1.5 – 41.1 mm T-3P: 3 – Point probes: Ø 4.75 – 150.6 mm T-T: probes to measure…
The modular design with extensive accessories enables gauging of most common bores. This allows a use for serial and individual control as well as preferentially in the plant directly at the production machine.
Range of application:
In addition to bore measurement, Diatest split-ball probes can detect geometrical shape defects such as ovality, concentricity, barrel-shape, etc.
A large assortment of accessories completes the split ball range. Sets of Diatest Split Ball probes in a wooden box can be purchased, e. g. with a measurement range of 3.7 to 9.8 mm. Mechanical indicators with a resolution of 0.01 resp. 0.001 mm can be used for display, or digital min-max indicators which can transfer the measured values via DIAWIRELESS. Special shapes and solutions on request.
If you have any kind of questions or any interests for our product, feel free to contact us here
Operating range:
Standard split-ball probe in hard chrome: Ø 0.47 – 41.1 mm
Standard split-ball probe with carbide contacts: Ø 1.5 – 41.1 mm (for heavy wear conditions)
Standard split-ball probe with ceramic contacts: Ø 3.7 – 41.1 mm (for soft materials like aluminium etc.)
Blind bore split-ball probe: Ø1.5 – 41.1 mm (for gauging close to bottom of bore)
3-point split-ball probe : Ø 4.75 – 150,6 mm (gauging of polygon-shaped workpieces)
T-probes: Ø 2.05 – 9.8 mm (for gauging deep bores with Ø smaller than 8.2 mm)
Measuring range:
0.06 mm up to 2.2 mm (according to size of probe)
Accuracies:
Repeatability (standard split-ball probes): Manual gauging c. 1 μm, Stationary gauging in stand < 0,5 μm
Linearity (standard split-ball probes): Size 0.5 – 1.50 max. 2% of travel, min. 0.001 mm Size 1.75 – 40 max. 1% Size 1.75 – 40 max. 1% of travel, min. 0.001 mm
Calibration with setting ring
Measuring depth:
Up to Ø 4.2 max. 750 mm (T-probes with TV2/TV2,5)
Ø > 4.2 – 8.3 max. 1000 mm (T-probes with TV4)
Ø > 8.3 – 41.1 several metres (standard split-ball probes with TV8)
Contact points:
Standard version in hard chrome, different materials like carbide, ceramic (depending on size).
Special shapes for blind bores, parallel distances (grooves)
Special shapes on request