Skip to content
PT Yakin Maju Sentosa

Bowers

CV-600 Basic Digital Series

Basic digital regular Rockwell type tester (CV-600BD/MBD) and Superficial Rockwell type tester (CV-600MBD/S) offering accuracy, reliability and durability at an extremely affordable price. Features Rugged construction, will stand u...

Product Description

Basic digital regular Rockwell type tester (CV-600BD/MBD) and Superficial Rockwell type tester (CV-600MBD/S) offering accuracy, reliability and durability at an extremely affordable price.

Features

  • Rugged construction, will stand up to the harshest environments
  • Direct reading of Rockwell scales HRA, B, C, D, E, F, G, K, L, M, P, R, S, V (CV-600BD/CV-600MBD) Superficial: HRN, T, W, X and Y (CV-600MBD/S)
  • Accuracy conforms to EN-ISO 6508 and ASTM E-18
  • Easy load force selection by robust dial knob
  • Oil brake with variable damping by adjustable knob (CV-600BD)
  • Large capacity to accommodate large test specimen
  • Selectable control of load duration (dwell time)
  • Motorised testing procedure (CV-600MBD & CV-600MBD/S)
  • Standard delivery including accessories ready for testing all scales
  • Support IOT

Standard delivery

  • Main unit
  • Diamond Rockwell indentor
  • Rockwell ball indentor 1/16"
  • Spare lamps 6V - 12W (2 pcs)
  • Hardness test block ±60HRC
  • Hardness test block ±25HRC
  • Hardness test block ±85HRB
  • Flat anvil ø 60 mm
  • Flat anvil ø 150 mm
  • V-anvil ø 40 mm
  • Power cable
  • Fuse 0.5A (2 pcs)
  • Adjustable feet (4 pcs)
  • Spindle protection cover
  • Solid accessories case
  • CV Instruments certificate
  • Installation & user manual

Optional accessories

  • Certified test blocks
  • Certified indentors & balls

Bowers

Contact us for a quote

Send us the model and quantity — our team replies with a quote and an estimated lead time.

Get a Price Quote Back to list

Specifications

Rockwell scales Standard

A,B,C,D,E,F,G,K,L,M,P,R,S,V (CV-600BD/CV-600MBD)

Superficial 

HRN, T, W, X & Y (CV-600MBD/S)

Hardness resolution

1 of a Rockwell unit

Test loads Rockwell

10kgf preload / 60, 100, 150kgf main load

Superficial Rockwell

3kgf preload / 15, 30, 45kgf main load

Display

Dial indicator

Test force application

By force lever (CV-600BD)

Motorised load system (CV-600MBD & CV-600MBD/S)

Test cycle

 

By force lever (CV-600BD)

Motorised load system (CV-600MBD & CV-600MBD/S)

Load duration

 

Manually, following display indication (CV-600BD)

Automatic (CV-600MBD & CV-600MBD/S)

Dwell time

1-99 sec (1 sec. step)

Measuring protocol

ISO / ASTM / JIS

Indications on display

Progress bar for preload, preload applied, main load applied, dwell time, invalid reading, invalid measurement, invalid procedure, Rockwell value, scale applied

Accuracy

Conforms to EN-ISO 6508 and ASTM E-18

Specimen accommodation

 

Vertical space 170mm (6.7")

Horizontal space (from center-line) 165mm (6.5")

Specimen access

External surfaces

Power supply

Non (600A), 220V 50Hz

Machine dimensions

150mm x 485mm x 700mm (WxDxH)

Machine weight

Approx. 85kg

Need help choosing?

Send us the application and the tolerance. We will cross-reference the catalogue and come back with the models that actually fit.